Call Us

We are ready to help

Request a special version

Didn't find what you were looking for?
This field cannot be empty.
This field must be at least 3 characters long.

Files

Drag & Drop files here or click to browse

File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb

Need to be uploaded up 1 to 3 files.
File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb
Leave your details so we can contact you
This field cannot be empty.
This field must be at least 3 characters long.
This field cannot be empty.
Please enter a valid email address.
This field cannot be empty.
Please enter a valid phone number.
This field cannot be empty.
Server error. Try again later.
Thank you!
We will send you a confirmation email and will contact you soon.
Don't have account yet? Register
Back to shopping
Art.Nr.: 12173

1-LA13K1.6/350_E

  • Straingage Single-Grid Pattern, 350 Ohm
  • connection: solder pad
  • Dimensions 5,7mm x 4,5mm
  • Gage length 1,60mm
  • Temperature compensation aluminium (23 ppm/° C)
  • Price per piece
  • weight 25 g
All details
Select variant:
Artikelbeschreibung
  • Straingage Single-Grid Pattern, 350 Ohm
  • connection: solder pad
  • Dimensions 5,7mm x 4,5mm
  • Gage length 1,60mm
  • Temperature compensation aluminium (23 ppm/° C)
  • Price per piece
  • weight 25 g
Product description

Strain gauges for the construction of sensors. The carrier material of this strain gauge is PEEKF with 40μm thickness. The constantan measuring grid (3 ... 5μm) is covered with PEEKF foil, also with 40μm thickness. As a result, this strain gage type is generally slightly thicker than comparable types with polyimide carrier and cover. In terms of handling, this DMS type is therefore somewhat more robust. Unlike polyimide, PEEKF is not hygroscopic, so that additional sealing of the upper polyimide cover film with epoxy resin is not necessary.

Due to the combination of PEEKF and Konstantan measuring grid, this Strain gauge type is particularly stable in the zero signal and is characterized by very low temperature-induced drift of the zero signal. The temperature-related drift due to expansion of the sensor body is compensated in a wide range from -10 ° C to + 120 ° C for the materials steel (variant 1) and aluminum (variant 3). The permitted operating range is from -40 ° C to + 200 ° C. There are 107 load cycles with ± 1000μm/m achieved with a shift of the zero signal less than 300μm/m.

The gage-factor of the Transduce strain gauges is approx. 2 and is not individualized unlike as for stress analysis gages. The tolerance of the gage factor for measuring grids up to 1.5mm grid length is ± 1.5%.

 

LatestProducts
1-LA13K1.6/350_E
1-LA13K1.6/350_E.pdf
Artikelbeschreibung
  • Straingage Single-Grid Pattern, 350 Ohm
  • connection: solder pad
  • Dimensions 5,7mm x 4,5mm
  • Gage length 1,60mm
  • Temperature compensation aluminium (23 ppm/° C)
  • Price per piece
  • weight 25 g
Product description

Strain gauges for the construction of sensors. The carrier material of this strain gauge is PEEKF with 40μm thickness. The constantan measuring grid (3 ... 5μm) is covered with PEEKF foil, also with 40μm thickness. As a result, this strain gage type is generally slightly thicker than comparable types with polyimide carrier and cover. In terms of handling, this DMS type is therefore somewhat more robust. Unlike polyimide, PEEKF is not hygroscopic, so that additional sealing of the upper polyimide cover film with epoxy resin is not necessary.

Due to the combination of PEEKF and Konstantan measuring grid, this Strain gauge type is particularly stable in the zero signal and is characterized by very low temperature-induced drift of the zero signal. The temperature-related drift due to expansion of the sensor body is compensated in a wide range from -10 ° C to + 120 ° C for the materials steel (variant 1) and aluminum (variant 3). The permitted operating range is from -40 ° C to + 200 ° C. There are 107 load cycles with ± 1000μm/m achieved with a shift of the zero signal less than 300μm/m.

The gage-factor of the Transduce strain gauges is approx. 2 and is not individualized unlike as for stress analysis gages. The tolerance of the gage factor for measuring grids up to 1.5mm grid length is ± 1.5%.

 