Call Us

We are ready to help

Request a special version

Didn't find what you were looking for?
This field cannot be empty.
This field must be at least 3 characters long.

Files

Drag & Drop files here or click to browse

File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb

Need to be uploaded up 1 to 3 files.
File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb
Leave your details so we can contact you
This field cannot be empty.
This field must be at least 3 characters long.
This field cannot be empty.
Please enter a valid email address.
This field cannot be empty.
Please enter a valid phone number.
This field cannot be empty.
Server error. Try again later.
Thank you!
We will send you a confirmation email and will contact you soon.
Don't have account yet? Register
Back to shopping
GSV-1H analog measuring amplifier - ME-Systems
GSV-1H analog measuring amplifier - ME-Systems
Art.Nr.: 3142

GSV-1H 010/2k5/2

  • 1- channel straingauge amplifier in DIN rail housing;
  • connection: 8 clamp connections;
  • dimensions: 12.5mm x 114.5mm x 99mm;
  • analog output: -10V...+10V;
  • limit frequency: 2,5kHz;
  • input sensitivity: 2 / 1 / 0.5 / 0.2 mV/V;
  • supply voltage: 11V..29V DC;
  • weight: 83 g;
  • environmental protection: IP40;

The measuring amplifier GSV-1H is ideal for mounting on DIN rails (according to DIN EN50022).

All details
Select variant:
Artikelbeschreibung
  • 1- channel straingauge amplifier in DIN rail housing;
  • connection: 8 clamp connections;
  • dimensions: 12.5mm x 114.5mm x 99mm;
  • analog output: -10V...+10V;
  • limit frequency: 2,5kHz;
  • input sensitivity: 2 / 1 / 0.5 / 0.2 mV/V;
  • supply voltage: 11V..29V DC;
  • weight: 83 g;
  • environmental protection: IP40;

The measuring amplifier GSV-1H is ideal for mounting on DIN rails (according to DIN EN50022).

Highlights
  • Taring function via control cable
  • 250Hz filter in the standard design
  • 2.5 kHz or 10 kHz filter optional
  • Amplification configurable
  • ±10V output signal
  • optional 4...20mA output signal
  • Supply from up  to 8 full bridges at 350 ohm
  • Connection of half and full bridges as an option
Product description

The measuring amplifier GSV-1H is available with voltage outputs ±10V and current output 4...20mA.

The current output can be factory configured for automatic zero adjustment to 4 mA (4 mA + 16mA, for "unipolar" measurements), or for an automatic zero adjustment to 12 mA (12 mA + -8 mA, for "bipolar" measurements).

Due to the high filter frequency of 250 Hz (2.5 kHz and 10 kHz optional), it is also perfectly suitable for dynamic measurements.

The force sensor is connected to terminals 1 to 4.

The voltage supply (11-28 volt) is connected to terminal 5 and 8 (ground).

To set to zero, terminal 6 is a brief (ca. 2 s) connected to the voltage supply or a control signal between 5 volt and 24 volt is applied. The status is permanently stored in an EEPROM.

Amplification can be switched 1-2-4-10 times via internal jumpers.

If the input signal becomes negative, output follows up to 0 mA.

LatestProducts
GSV-1H 010/2k5/2
GSV-1H 010/2k5/2.pdf
GSV-1H 010/2k5/2
GSV-1H-step.zip
Artikelbeschreibung
  • 1- channel straingauge amplifier in DIN rail housing;
  • connection: 8 clamp connections;
  • dimensions: 12.5mm x 114.5mm x 99mm;
  • analog output: -10V...+10V;
  • limit frequency: 2,5kHz;
  • input sensitivity: 2 / 1 / 0.5 / 0.2 mV/V;
  • supply voltage: 11V..29V DC;
  • weight: 83 g;
  • environmental protection: IP40;

The measuring amplifier GSV-1H is ideal for mounting on DIN rails (according to DIN EN50022).

Highlights
  • Taring function via control cable
  • 250Hz filter in the standard design
  • 2.5 kHz or 10 kHz filter optional
  • Amplification configurable
  • ±10V output signal
  • optional 4...20mA output signal
  • Supply from up  to 8 full bridges at 350 ohm
  • Connection of half and full bridges as an option
Product description

The measuring amplifier GSV-1H is available with voltage outputs ±10V and current output 4...20mA.

The current output can be factory configured for automatic zero adjustment to 4 mA (4 mA + 16mA, for "unipolar" measurements), or for an automatic zero adjustment to 12 mA (12 mA + -8 mA, for "bipolar" measurements).

Due to the high filter frequency of 250 Hz (2.5 kHz and 10 kHz optional), it is also perfectly suitable for dynamic measurements.

The force sensor is connected to terminals 1 to 4.

The voltage supply (11-28 volt) is connected to terminal 5 and 8 (ground).

To set to zero, terminal 6 is a brief (ca. 2 s) connected to the voltage supply or a control signal between 5 volt and 24 volt is applied. The status is permanently stored in an EEPROM.

Amplification can be switched 1-2-4-10 times via internal jumpers.

If the input signal becomes negative, output follows up to 0 mA.