Call Us

We are ready to help

Request a special version

Didn't find what you were looking for?
This field cannot be empty.
This field must be at least 3 characters long.

Files

Drag & Drop files here or click to browse

File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb

Need to be uploaded up 1 to 3 files.
File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb
Leave your details so we can contact you
This field cannot be empty.
This field must be at least 3 characters long.
This field cannot be empty.
Please enter a valid email address.
This field cannot be empty.
Please enter a valid phone number.
This field cannot be empty.
Server error. Try again later.
Thank you!
We will send you a confirmation email and will contact you soon.
Don't have account yet? Register
Back to shopping
analog measuring amplifier as printed circuit board with autozero and autoscale function
analog measuring amplifier as printed circuit board with autozero and autoscale function
analog measuring amplifier as printed circuit board with autozero and autoscale function
analog measuring amplifier as printed circuit board with autozero and autoscale function
Art.Nr.: 9798

GSV-13q 010-5/1000/2

  • 1-channel strain gauge amplifier as printed circuit board;
  • Dimensions: 22 mm x 11 mm x 4 mm;
  • Analog output 0.05V ... 10V, 1000S/s;
  • Autoscale function for input sensitivity 0.1 ... 3.0 mV/V;
  • Autozero function for zeroing to 5V;
  • Supply voltage 14V..28V DC;
  • Weight 5 g;
All details
Select variant:
Artikelbeschreibung
  • 1-channel strain gauge amplifier as printed circuit board;
  • Dimensions: 22 mm x 11 mm x 4 mm;
  • Analog output 0.05V ... 10V, 1000S/s;
  • Autoscale function for input sensitivity 0.1 ... 3.0 mV/V;
  • Autozero function for zeroing to 5V;
  • Supply voltage 14V..28V DC;
  • Weight 5 g;
Highlights
  • Analog output 0-10 volts
  • Supply voltage 14V ... 28V DC
  • Solder pads for strain gauge connection
  • automatic zero adjustment to 5V via control input "Tare"
  • automatic scaling via control input "Scale"
Product description

The measuring amplifier GSV-13q is suitable for installation in sensors with strain gages, for example in force sensors, torque sensors, load cells.

The measuring amplifier is characterized by very small dimensions of only 22 mm in length and 4 mm in thickness. The fixing can be done with the help of 2 fixing straps and M2 screws.

The measuring amplifier GSV-13q has an automatic zero adjustment via control line "Tare" and an automatic scaling function "Scale". To set the characteristic, "Tare" is triggered in the unloaded state. In the loaded condition with 100% load, the gain is adjusted via the control line "Scale".

These functions allow zero calibration, calibration and adjustment to be performed in one set-up on the finished product. In contrast to the predecessor model GSV-13L, no strain gauge resistors have to be exchanged for zero point and gain adjustment.

The measured values ​​at the analog output are updated with a frequency of 1 kHz.

To trigger the functions "Tare" and "Scale", the corresponding inputs "Ta" and "Sc" are connected to the operating voltage (14V ... 28V) for a period of 3s. The functions are executed on the falling edge. The "automotive" variant GSV-13q 05-2.5 / 1000/2 works safely from a supply voltage of 9V to 28V.

The functions "Tare" and "Scale" can be deactivated independently of each other, so that e.g. only the "Tare" function can be executed or that both functions are activated or deactivated.

The variants with voltage output 0 ... 10V, zero adjustment to 5V and 4 ... 20mA, zero adjustment to 12mA, are order options. Other variants, e.g. with zero adjustment to 4mA or zero adjustment to 0.5V we are happy to deliver as customer-specific version.

Noise Amplitude

  • Noise amplitude about 2 µV/V Pk-Pk bei 10 Hz Bandwidth
  • Noise amplitude about 20 µV/V Pk-Pk bei 1 kHz Bandwidth

Similar products:

  • GSV-13i: Dimensions Ø 18 mm, height 4 mm, technically largely identical to GSV-13q
  • GSV-15L: Dimensions 16mm x 33mm x 5mm, readings at analogue output are updated at 105Hz
  • GSV-5L: Dimensions 23 mm x 20 mm x 6 mm, Measuring amplifier with "real analog output" (time and value continuous) and best signal-to-noise ratio
  • GSV-6L: Dimensions 22mm x 14mm x 9mm, configurable from 10Hz to 25kHz, current / voltage / offset
  • GSV-14l: dimensions 13 mm x 27 mm x 5 mm, 1.5 volts; Stroke ± 1.25 volts, adjustment via SMD resistors, for battery operation, with enable input; Operating voltage 3.4V ... 10V;
  • GSV-6CPU: Dimensions 19mm x 14mm x 4mm, UART interface, analog output 1.5V ± 1V, configurable from 10Hz to 25kHz
LatestProducts
GSV-13q 010-5/1000/2
GSV-13q 010-5/1000/2.pdf
GSV-13q 010-5/1000/2
GSV-13q_11x22_Rev01.zip
GSV-13q 010-5/1000/2
GSV-13q_11x22-2.png
GSV-13q 010-5/1000/2
ba-gsv13_en.pdf
Artikelbeschreibung
  • 1-channel strain gauge amplifier as printed circuit board;
  • Dimensions: 22 mm x 11 mm x 4 mm;
  • Analog output 0.05V ... 10V, 1000S/s;
  • Autoscale function for input sensitivity 0.1 ... 3.0 mV/V;
  • Autozero function for zeroing to 5V;
  • Supply voltage 14V..28V DC;
  • Weight 5 g;
Highlights
  • Analog output 0-10 volts
  • Supply voltage 14V ... 28V DC
  • Solder pads for strain gauge connection
  • automatic zero adjustment to 5V via control input "Tare"
  • automatic scaling via control input "Scale"
Product description

The measuring amplifier GSV-13q is suitable for installation in sensors with strain gages, for example in force sensors, torque sensors, load cells.

The measuring amplifier is characterized by very small dimensions of only 22 mm in length and 4 mm in thickness. The fixing can be done with the help of 2 fixing straps and M2 screws.

The measuring amplifier GSV-13q has an automatic zero adjustment via control line "Tare" and an automatic scaling function "Scale". To set the characteristic, "Tare" is triggered in the unloaded state. In the loaded condition with 100% load, the gain is adjusted via the control line "Scale".

These functions allow zero calibration, calibration and adjustment to be performed in one set-up on the finished product. In contrast to the predecessor model GSV-13L, no strain gauge resistors have to be exchanged for zero point and gain adjustment.

The measured values ​​at the analog output are updated with a frequency of 1 kHz.

To trigger the functions "Tare" and "Scale", the corresponding inputs "Ta" and "Sc" are connected to the operating voltage (14V ... 28V) for a period of 3s. The functions are executed on the falling edge. The "automotive" variant GSV-13q 05-2.5 / 1000/2 works safely from a supply voltage of 9V to 28V.

The functions "Tare" and "Scale" can be deactivated independently of each other, so that e.g. only the "Tare" function can be executed or that both functions are activated or deactivated.

The variants with voltage output 0 ... 10V, zero adjustment to 5V and 4 ... 20mA, zero adjustment to 12mA, are order options. Other variants, e.g. with zero adjustment to 4mA or zero adjustment to 0.5V we are happy to deliver as customer-specific version.

Noise Amplitude

  • Noise amplitude about 2 µV/V Pk-Pk bei 10 Hz Bandwidth
  • Noise amplitude about 20 µV/V Pk-Pk bei 1 kHz Bandwidth

Similar products:

  • GSV-13i: Dimensions Ø 18 mm, height 4 mm, technically largely identical to GSV-13q
  • GSV-15L: Dimensions 16mm x 33mm x 5mm, readings at analogue output are updated at 105Hz
  • GSV-5L: Dimensions 23 mm x 20 mm x 6 mm, Measuring amplifier with "real analog output" (time and value continuous) and best signal-to-noise ratio
  • GSV-6L: Dimensions 22mm x 14mm x 9mm, configurable from 10Hz to 25kHz, current / voltage / offset
  • GSV-14l: dimensions 13 mm x 27 mm x 5 mm, 1.5 volts; Stroke ± 1.25 volts, adjustment via SMD resistors, for battery operation, with enable input; Operating voltage 3.4V ... 10V;
  • GSV-6CPU: Dimensions 19mm x 14mm x 4mm, UART interface, analog output 1.5V ± 1V, configurable from 10Hz to 25kHz
LatestProducts
GSV-13q 010-5/1000/2
GSV-13q 010-5/1000/2.pdf
GSV-13q 010-5/1000/2
GSV-13q_11x22_Rev01.zip
GSV-13q 010-5/1000/2
GSV-13q_11x22-2.png
GSV-13q 010-5/1000/2
ba-gsv13_en.pdf
GSV-13q 010-5/1000/2
bars-filter