Call Us

We are ready to help

Request a special version

Didn't find what you were looking for?
This field cannot be empty.
This field must be at least 3 characters long.

Files

Drag & Drop files here or click to browse

File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb

Need to be uploaded up 1 to 3 files.
File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb
Leave your details so we can contact you
This field cannot be empty.
This field must be at least 3 characters long.
This field cannot be empty.
Please enter a valid email address.
This field cannot be empty.
Please enter a valid phone number.
This field cannot be empty.
Server error. Try again later.
Thank you!
We will send you a confirmation email and will contact you soon.
Don't have account yet? Register
Back to shopping
Art.Nr.: 11459

K6D-CalibrationMatrix SL/4

  • Calibration matrix with error compensation for 6-axis force/torque sensors up to 20kN
  • for one nominal load
  • nominal load vector: standard or according to customer requirements
  • 4-point calibration
  • 3 measurement series with 4 measuring points each; "3 support points"
  • up and down row, compressive force, tensile force, pos. Neg. Moment
  • 0%, 10%, 50%, 100%, 0%
  • 0%, -10%, -50%, -100%, 0%
  • 12x5x3 measurements
  • 12 orientations along the coordinate axes
  • attaching a calibration mark to the device
  • 36 calibration factors for scaling the sensor output signals to Fx, Fy, Fz, Mx, My, Mz
  • factory calibration certificate with traceability to DAkkS standard parts
  • the calibration matrix is a necessary component for the operation of the multi-axis sensors K6D and F6D
  • incl. Matrix-Plus for correction matrix of the second degree
  • calibration matrix with highest accuracy for 6-axis force/torque sensors
  • additional "Matrix B" for error compensation to the order of 0.2%... 0,5%
All details
Select variant:
Artikelbeschreibung
  • Calibration matrix with error compensation for 6-axis force/torque sensors up to 20kN
  • for one nominal load
  • nominal load vector: standard or according to customer requirements
  • 4-point calibration
  • 3 measurement series with 4 measuring points each; "3 support points"
  • up and down row, compressive force, tensile force, pos. Neg. Moment
  • 0%, 10%, 50%, 100%, 0%
  • 0%, -10%, -50%, -100%, 0%
  • 12x5x3 measurements
  • 12 orientations along the coordinate axes
  • attaching a calibration mark to the device
  • 36 calibration factors for scaling the sensor output signals to Fx, Fy, Fz, Mx, My, Mz
  • factory calibration certificate with traceability to DAkkS standard parts
  • the calibration matrix is a necessary component for the operation of the multi-axis sensors K6D and F6D
  • incl. Matrix-Plus for correction matrix of the second degree
  • calibration matrix with highest accuracy for 6-axis force/torque sensors
  • additional "Matrix B" for error compensation to the order of 0.2%... 0,5%