Call Us

We are ready to help

Request a special version

Didn't find what you were looking for?
This field cannot be empty.
This field must be at least 3 characters long.

Files

Drag & Drop files here or click to browse

File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb

Need to be uploaded up 1 to 3 files.
File format supported: (.pdf, .zip, .docx, .png, .jpg .xlsx, .xls, .csv, .txt) & Max Filesize: 25mb
Leave your details so we can contact you
This field cannot be empty.
This field must be at least 3 characters long.
This field cannot be empty.
Please enter a valid email address.
This field cannot be empty.
Please enter a valid phone number.
This field cannot be empty.
Server error. Try again later.
Thank you!
We will send you a confirmation email and will contact you soon.
Don't have account yet? Register
Back to shopping
KD80s s-type force sensor - ME-Systems
KD80s s-type force sensor - ME-Systems
Art.Nr.: 10047

KD80se 1kN/010-5

  • type: s-form force sensor
  • nominal force: 1 kN
  • accuracy class: 0.5
  • dimensions: 50 mm x 60 mm x 12,5 mm
  • force transmission: 2 x female thread M8x1,25
  • connection: 5 m Unitronic FD CP Plus 3x2x0,14
  • integrated electronics GSV 13q
  • analog output 0.05 ... 10V, 1000S/s
  • autoscale function for input sensitivity 0.1 ... 3.0 mV/V
  • autozero function for zeroing to 5V
  • auto scale function for input sensitivity
  • material: stainless steel
  • nominal output: 2 mV/V
All details
Select variant:
Artikelbeschreibung
  • type: s-form force sensor
  • nominal force: 1 kN
  • accuracy class: 0.5
  • dimensions: 50 mm x 60 mm x 12,5 mm
  • force transmission: 2 x female thread M8x1,25
  • connection: 5 m Unitronic FD CP Plus 3x2x0,14
  • integrated electronics GSV 13q
  • analog output 0.05 ... 10V, 1000S/s
  • autoscale function for input sensitivity 0.1 ... 3.0 mV/V
  • autozero function for zeroing to 5V
  • auto scale function for input sensitivity
  • material: stainless steel
  • nominal output: 2 mV/V
Product description

The force sensor KD80se is used for tensile and compressive force measurements and for weighing.

Fields of application are e.g. Rope force measurements, test benches, overload protection for lifting equipment, process controls and scales.

The KD80se sensors have an integrated GSV-13q measuring amplifier with analogue output. The supply voltage is 14 ...28V DC Unlike the GSV-6L integratable measuring amplifier, the GSV-13i is not configurable via the ClickRClackR menu. The integrated measuring amplifier GSV-13i focuses on smallest dimensions, zero setting and scaling function. In contrast, filter functions and resolution with 600 nV/V ... 20 µV/V noise amplitude PkPk not suitable for high resolution applications. For high resolutions the use of an external measuring amplifier is recommended.

The KD80se sensors correspond to accuracy class 0.5. The protection class is IP65.

Recommended products
LatestProducts
KD80se 1kN/010-5
KD80se 1kN/010-5.pdf
KD80se 1kN/010-5
kd80s_500n-1kn.pdf
Artikelbeschreibung
  • type: s-form force sensor
  • nominal force: 1 kN
  • accuracy class: 0.5
  • dimensions: 50 mm x 60 mm x 12,5 mm
  • force transmission: 2 x female thread M8x1,25
  • connection: 5 m Unitronic FD CP Plus 3x2x0,14
  • integrated electronics GSV 13q
  • analog output 0.05 ... 10V, 1000S/s
  • autoscale function for input sensitivity 0.1 ... 3.0 mV/V
  • autozero function for zeroing to 5V
  • auto scale function for input sensitivity
  • material: stainless steel
  • nominal output: 2 mV/V
Product description

The force sensor KD80se is used for tensile and compressive force measurements and for weighing.

Fields of application are e.g. Rope force measurements, test benches, overload protection for lifting equipment, process controls and scales.

The KD80se sensors have an integrated GSV-13q measuring amplifier with analogue output. The supply voltage is 14 ...28V DC Unlike the GSV-6L integratable measuring amplifier, the GSV-13i is not configurable via the ClickRClackR menu. The integrated measuring amplifier GSV-13i focuses on smallest dimensions, zero setting and scaling function. In contrast, filter functions and resolution with 600 nV/V ... 20 µV/V noise amplitude PkPk not suitable for high resolution applications. For high resolutions the use of an external measuring amplifier is recommended.

The KD80se sensors correspond to accuracy class 0.5. The protection class is IP65.